EasyWire Base Unit
Call or Email For Quote
The GHK Easywire makes wiring an environmental controller easier! An Easy-Wire uses 2 heating steps to control 2 unit heaters and controls a variety of cooling equipment, such as single or dual speed fans and proportional ventilation, depending on the model. Plus, all Easy-Wires have DIF, DAY and NITE stages, a dehumidification vent cycle, an alarm and more! The relay box has 30 Amp relays and an easy connection terminal strip. Easy-Wire-1 and -2 are pre-wired to the GHK12X2 controller. The Easy-Wire-1 is equipped for single speed fans. The Easy-Wire-2 is equipped for dual speed fans.
***Our EasyWire boxes are custom made for each greenhouse. Be sure to fill out an equipment list for the greenhouse when you place your order. Includes a 50VA transformer. 100VA transformer will incur additional costs.
- Features
-
*Programmable for 1 or 2 zones
*2 thermistors, each with 25' of wire, included
*DIF, DAY, and NITE settings for each zone
*4 COOL and 2 HAF relay outputs source 24 VAC
*2 HEAT outputs are open/closed contacts or source 24 VAC
*Automatic or manual settings for each HEAT or COOL output
*1 TIMER output for irrigation or lights
*ALARM output (High Temperature, Low Temperature, Power Loss)
*Vent Stage for dehumidification
*Programmable delay for HEAT-COOL (COOL-HEAT) transitions
*Statistics - min and max temperature, 7 days of averages for DIF, DAY, NITE, and 24hr.
*Override of temperature settings for temporary adjustment
*24 hour clock and memory with battery back-up
*Remote control and programming with C.I.S. (Computer Interface Software) - Specifications
-
Bartlett Item ID AEZ775 Controller Dimensions: 7.17 x7.09
x3.54"Standard Relay Cabinet Dimensions: 18 x12
x6"XL Relay Cabinet Dimensions: 18 x18
x6"Optional Sealed Enclosure: 16 x14
x6"Cable Length: Approx. 6ft. Transformer 50VA, included. 100VA at additional cost - Documentation
- Videos
*Programmable for 1 or 2 zones
*2 thermistors, each with 25' of wire, included
*DIF, DAY, and NITE settings for each zone
*4 COOL and 2 HAF relay outputs source 24 VAC
*2 HEAT outputs are open/closed contacts or source 24 VAC
*Automatic or manual settings for each HEAT or COOL output
*1 TIMER output for irrigation or lights
*ALARM output (High Temperature, Low Temperature, Power Loss)
*Vent Stage for dehumidification
*Programmable delay for HEAT-COOL (COOL-HEAT) transitions
*Statistics - min and max temperature, 7 days of averages for DIF, DAY, NITE, and 24hr.
*Override of temperature settings for temporary adjustment
*24 hour clock and memory with battery back-up
*Remote control and programming with C.I.S. (Computer Interface Software)
Bartlett Item ID | AEZ775 |
Controller Dimensions: | 7.17x7.09x3.54" |
Standard Relay Cabinet Dimensions: | 18x12x6" |
XL Relay Cabinet Dimensions: | 18x18x6" |
Optional Sealed Enclosure: | 16x14x6" |
Cable Length: | Approx. 6ft. |
Transformer | 50VA, included. 100VA at additional cost |
Wire Diagrams | ![]() |
Installation Manual | ![]() |
Product Info Sheet | ![]() |
User Manual | ![]() |