Cone and Thermocouple Offsets

Cone Offset

CnoS – Cone Offset is used to raise or lower the final temperature that is reached using the Cone Fire mode. The following apply to cone offsets:

 

Thermocouple Offset*

TCoS – Thermocouple (T/C) Offset is used to raise or lower the temperature that is indicated by the controller. The following apply to T/C offsets:

* T/C OFFSET is available on the V6-CF controller using the SMT600 circuit board (first manufactured March 1999).

 

  CONE Offset T/C Offset
To Correct Under-firing Set positive (00) cone offset

Set negative (90) t/c offset

To Correct Over-firing

Set negative (90) cone offset

Set positive (00) t/c offset

How to Change:

V6-CF:
Press OTHER til CnoS. Press ENTER.
Enter cone #.
Press ENTER.
Enter offset amount.
Press ENTER.

THP600 (RED panel):
*,1, 9, 9, 9.
Press ENTER.
Enter cone #.
Press ENTER.
enter offset amount.
Press ENTER.

V6-CF (single zone):
Press OTHER til tCOS.
Press ENTER.
Enter offset amount.
Press ENTER.

V6-CF (multiple zones):
Press OTHER til tCOS.
Press ENTER.
Press ENTER.
Enter offset amount for TC 1.
Press ENTER.
Press ENTER.
Enter offset amount for TC 2.
Press ENTER.
Press ENTER.
Enter offset amount for TC 3.
Press ENTER.

THP600 (RED panel):
not available

 

 